Integrated treatment systems

Integrated UV + Ozone Water Treatment Systems

Coordinated treatment trains for projects that need oxidation, controlled ozone contact and a final UV disinfection barrier—selected from the actual water analysis and process objective.

When integration makes sense

More than two machines on the same pipe

An integrated system is justified when the treatment objective needs distinct process steps. The sequence is confirmed from water quality, contaminant demand, microbial targets and downstream requirements.

Oxidation first

Reduce an oxidation load before final disinfection

Ozone may be used for color, odor or selected oxidizable constituents, followed by a separately sized UV barrier.

Multiple barriers

Separate oxidation and microbial-control duties

Each stage has a defined objective, monitoring point and operating limit rather than one generator capacity standing in for the complete process.

Process upgrade

Integrate with existing filtration or contact equipment

Existing tanks, pumps, filters and controls are reviewed before adding ozone injection, off-gas management or a UV reactor.

Reference treatment routes

Useful starting points—not fixed recipes

These arrangements illustrate common process logic. Final sequencing and equipment depend on the actual water and the required result.

Oxidation + final barrier

Ozone → Contact → UV

For duties where ozone provides the oxidation step and UV provides a final microbial-control barrier after the required contact stage.

Residual management

Ozone → Contact → Carbon → UV

For processes that require oxidation, downstream residual or by-product management, and final UV disinfection where appropriate.

Water-quality protection

Pretreatment → Ozone → Contact → UV

Filtration or other pretreatment may be required to manage solids, UV transmittance or ozone demand before the core treatment stages.

Recirculating systems

Side-stream Ozone + Main-Line UV

For selected recirculating-water duties where ozone contact and residual control are separated from the main UV treatment line.

Two separate design bases

Ozone and UV must be sized independently

A combined process does not create one interchangeable dose number. Each technology needs its own verified inputs and performance basis.

Ozone stage

Oxidation demand and mass transfer

Review the target constituent, water volume or flow, ozone demand, feed gas, gas concentration, transfer method, contact time, temperature, off-gas and the required residual or endpoint.

UV stage

Hydraulics, UVT and target dose

Review peak and design flow, UV transmittance, target microorganism or validation basis, lamp aging, fouling, reactor hydraulics, monitoring and redundancy.

System blocks

Configure the complete treatment train

Puritor organizes the equipment around the process duty instead of presenting supporting components as unrelated product lines.

01 / Gas preparation

Oxygen supply and ozone generation

Air or oxygen feed, drying where required, ozone production, cooling, gas-flow control and output verification.

02 / Water transfer

Injection, mixing and contact

Venturi or alternative injection, static or mechanical mixing, contact volume, pressure conditions and gas-liquid separation.

03 / Final barrier

UV reactor and controls

Closed-vessel or project-specific UV stage selected around flow, UVT, dose, lamp configuration, instrumentation and service access.

04 / Monitoring and safety

Residual, off-gas and interlocks

Dissolved ozone or ORP where appropriate, UV intensity monitoring, off-gas destruction, ventilation, alarms and coordinated shutdown logic.

Important limitations

Do not specify UV + ozone by label alone

The treatment route should remain testable and explainable. Where water chemistry or oxidation demand is uncertain, laboratory or pilot work may be more reliable than increasing nominal equipment capacity.

  • Not every project needs both UV and ozone.
  • UV plus ozone is not automatically an advanced oxidation process.
  • Generator output does not by itself define transferred ozone dose.
  • UV dose and ozone dose are not interchangeable.
  • Materials, residual management and site safety remain part of the design.

Start with the water

Send the process conditions—not only a target generator size

Share flow, water source, available analysis, treatment objective, existing equipment and operating constraints. Puritor will identify the missing inputs and recommend the next engineering step.